Quick diagnosis
Remove the drip tray and grounds container for several seconds while the machine is in the state described by JURA, clean and dry them, clear loose grounds from the bay, and reinstall both flush. The machine must detect removal, not only an empty bin.
What this symptom usually means
A message that remains after the tank, tray, grounds bin, or brew group is corrected usually means the machine has not seen the expected remove-and-reinsert sequence, a float is stuck, or a contact area is dirty.
Model-specific context: Avoid removing the tray during a moving or rinsing cycle. Wait until the display asks for it.
Clues to record before touching the machine
The fastest diagnosis comes from recording the machine's state before it is changed. Use your phone for a short video and write down whether the symptom occurs at startup, while heating, during grinding, after the pump starts, or during shutdown.
- Container was emptied without full removal
- Tray is damp underneath
- Message changes when tray is pressed inward
- Remove the named part while the machine is on if the manual allows
- Wait five to ten seconds
Most likely causes, in diagnostic order
The list below is ordered from common and externally testable conditions toward causes that may need qualified service. It is not a replacement for the error table or safety instructions for your exact model.
- Removal cycle was not detected
- Tray is not seated
- Contact area is dirty or wet
- Float or magnet is stuck
- Container was emptied without being removed long enough
- Contact or optical area is dirty
- A part is not fully seated
The 60-second separating test
Do not begin by replacing parts or repeating the full maintenance cycle. Complete these checks in order and stop if the machine behaves abnormally.
- Remove the named part while the machine is on if the manual allows
- Wait five to ten seconds
- Clean and dry contact areas
- Reinsert until it sits flush
Illustrated video walkthrough
Original 8-second silent, captioned diagnostic animation. It is an illustrated decision guide, not footage of this exact machine.
Safe fixes, easiest first
- Follow the exact remove, empty, and reinsert sequence
- Free a removable float with gentle rinsing
- Dry moisture near contacts
- Check for grounds behind the tray or bin
- Restart once after reassembly
- Arrange service if the message never changes
How to interpret what happens next
Message clears after delayed reinsertion: detection timing caused it
Message changes when the part moves: seating or contact is involved
Message remains with a known-good part position: sensor service may be needed
Intermittent message during operation: debris or alignment is likely
Common misdiagnosis
Simply emptying a bin in place may not reset a counter. Many machines must detect that the container was physically removed.
When to stop troubleshooting
Owner-level checks end when the next step would expose wiring, a heater, pressurized plumbing, sharp internal parts, or a sealed grinder. Stop and contact the manufacturer or a qualified appliance technician when any of these apply:
- A moving brew group is blocked
- A part requires force
- Liquid is near electronics
- The machine grinds or moves unexpectedly with a door open
Prevent the problem from returning
- Empty and clean containers before they overfill
- Keep tracks and contact areas dry
- Do not slam trays or service doors
Sources and verification
This page paraphrases owner-level manufacturer guidance and adds an original symptom-first decision path. It does not reproduce a manual. Exact button sequences should always be checked against the model label and current official instructions.
- JURA product support - official manufacturer information used to verify model terminology and owner-level procedures.
- JURA FAQ - official manufacturer information used to verify model terminology and owner-level procedures.
Editorial status: desk-researched against official support material; diagnostic media are original illustrations. We do not claim hands-on testing of this exact machine. See our evidence labels and report a correction.